ROCAS 522 AC
High-capacity BESS
Large-capacity cabinet integrating battery, PCS, EMS, BMS, liquid cooling and fire protection. Supports peak shaving, demand response and parallel expansion.
- Energy
- 522 kWh
- Power
- 250 kW
- Cell
- LFP 314 Ah
- Cooling
- Liquid
- Dimensions
- 1,900 × 1,350 × 2,300 mm
- Weight
- 5,340 kg
Download datasheetDiscuss this system
PDF, English, 452 KB
Technical specifications
AC / grid-connected
| Rated output | 250 kW |
|---|---|
| Overload | 1.1× continuous; 1.2× for 1 min |
| Rated voltage / wiring | 400 V (-15% to +15%); 3P+N+PE |
| Rated current | 360 A |
| Power factor | -1 to +1 |
| Grid frequency | 50/60 Hz ±2.5 Hz |
| THDI | ≤3% |
AC / off-grid
| Voltage | 400/380 V ±3% |
|---|---|
| Frequency | 50/60 Hz |
| THDU | <3% with linear load |
| Unbalanced load | 100% |
Battery
| Cell chemistry / rating | LFP; 3.2 V / 314 Ah |
|---|---|
| Configuration | 2P260S |
| Energy at 25°C / 0.5P | 522.496 kWh |
| DC range / nominal | 702–936 V / 832 V |
| Cycle life | 8,000 cycles (0.5P, 25 ±2°C, 70% SOH) |
System / environment
| Off-grid switching | <20 ms |
|---|---|
| Dimensions W × D × H | 1,900 × 1,350 × 2,300 mm |
| Weight | 5,340 kg |
| Noise | <75 dB |
| Enclosure / battery pack | IP54 / IP67 |
| System efficiency | ≥88% |
| Ambient temperature | -30 to +55°C |
| Humidity | ≤95% RH, non-condensing |
| Cooling | Liquid cooling |
| Fire suppression | Aerosol |
| Communications | Ethernet / CAN / RS485 |
| Maximum altitude | 2,000 m |
| Standards* | IEC 62933; IEC 62477; IEC 62619; IEC 63056; IEC 61000; UN 38.3 |
Specifications are indicative and refer to the standard configuration. Final values, certificates and warranty terms are confirmed in the project-specific technical offer.
* Standards referenced in the product documentation. Model-specific conformity documents are provided for project review.